Kickplates
Push plates or kickplates can be of the below permitted materials and can be either surface mounted or recessed flush. Fixing may be via screws or contact adhesive only.
- Steel (mild or Stainless) flat or checkerplate up to 2 mm thick (max. 200 mm high)
- Acrovyn 4000 up to 3 mm thick (up to min. 50 mm within lockset or furniture)
- Korogard 1.5 mm thick (up to min. 50 mm within lockset or furniture)
- Acrovyn 2000 1.5 mm thick (any size)
- Korogard 500 1.5 mm thick (any size)
- Steel (mild or stainless) up to 1 mm thick (any size)
- Aluminium up to 1 mm thick (any size)
All kickplates should be cut to fit between frame stops when mounted on the blank face of the door leaf.
Ventilation Grilles

Lorient LVH intumescent grilles are available in the following sizes:
- 300 x 300 mm
- 450 x 450 mm
- 600 x 300 mm
- 600 x 600 mm
Please note that fire doors with ventilation grilles cannot be certified as ‘Smoke control' door sets.
Two such Intumescent grilles may be fitted to each leaf separated from each other and hardware by at least 200mm (only one 600 x 600 mm grille allowed per leaf).
Grilles in exterior doors require an additional, custom made cover plate.
Please note that the insulation rating of a door set with a Grille in it can be no greater than 30 minutes.
Drop shutter grilles are not an option on this doorset.
Bolection Moulds
Bolection moulds must not extend to the edge of the leaf (120 mm minimum from side edges and 140 mm minimum from top edge). Care should be taken to ensure they don't clash with any door hardware or furniture.
Bolection moulds can be to one or both faces of a leaf.
Example patterns:

V-GROOVES
V-grooves can be machined into the leaf facings for aesthetic purposes.
The following restrictions apply:
- Leaf facing has to be MDF or ply.

Adjacent Doors
Adjacent fire rated doors are permitted provided the central mullion is grouted, reinforced steel. Maximum leaf width is 1200 mm. Maximum width of the coupled doorsets is 7500mm overall (max. 3 pair doorsets in a sequence).
Adjacent doors are not permitted for fire rated door sets installed into Speedwall.
Decorative Panels
Decorative panels fixed to the face of the door leaf have been removed as a compliant option for this door type.