The door set is rated to level 3 of the European standard ENV 1627-30:1999 “Windows, doors, shutters – Burglar resistance”. This testing incorporates a static load test with applied loads of up to 600 kg as well as manual attack for 5 minutes with a range of hand tools.
Hardware
The tested and certified door set can only be fitted with specific Mottura multipoint locking hardware. Any additional hardware required must be specified in detail at the time of ordering so that correct preparation of the steel door leaf and frame can be made. This includes any door furniture or items which may be screw-fixed to or through the outside face.
Closer
Surface-mounted closers mounted on the inside face are recommended.
Hinges
The leaf is hung on four surface mounted 100x47mm stainless steel hinges.
Mottura multipoint locking system
For the emergency exit door a Mottura 86.530 lock case is internally mounted in the leaf. The lock case has two horizontal locking bolts plus a latch bolt and it also controls an additional two lock bolts near the top and bottom edge of the leaf.
All lock bolts and the latch are operated by a panic exit bar. The panic exit device requires a key to re-lock. More information regarding this locking system is available upon request.
For the standard multipoint lock a Mottura 85.371 lock case is internally mounted in the leaf. The lock case has four horizontal locking bolts plus a latch bolt and it also controls an additional two lock bolts near the top and bottom edge of the leaf. A handle operates the latch bolt only, while the key operates the lock bolts.
The lock can be fitted with any double sided europrofile cylinder. The use of an Abloy “Protec” cylinder or similar is recommended for maximum security. A protective cover can be fitted to the lock if further cylinder protection is required.