Installation wall framing requirements
Pacific X-Ray Barrier Window
Frame materials available:
- EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
Fasteners:
- Frame to be screw fixed (10g x 75mm self tapping) at 600mm nominal centres. Two fasteners per location.
Stud size:
- Ex 100 x 50 minimum
Wedging gap:
- N/A
Frame materials available:
- EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
Fasteners:
- Frame to be screw fixed (10g x 75mm self tapping) at 600mm nominal centres. Two fasteners per location.
Stud size:
- Ex 100 x 50 minimum
Wedging gap:
- N/A