Installation wall framing requirements

Pacific Hospital Double Action Door Set

WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Recommended Fasteners:

  • Frame screwed to stud through packing.
  • Frame to be screw fixed (10g x 100mm self tapping) at 600mm nominal centres. Two fasteners per location

Head Fixing:

Single door: None required
Pair door: Double central fasteners

Wedging gap:

  • 5-10 mm

 

H-D-DA-S-T-1 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:
EGZ - 1.6mm

  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Recommended Fasteners:
Frame screwed to stud through packing.
Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location


Head Fixing:
Single door: None required
Pair door: Double central fasteners


Wedging gap:

  • N/A

 

H-D-DA-S-T-2 image
WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 1.6mm
  • Cold rolled galvanized - 1.6mm
  • Stainless Steel - 1.5mm

Recommended Fasteners:
Frame screwed to stud through packing.
Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location


Head Fixing:
Single door: None required
Pair door: Double central fasteners


Wedging gap:

  • N/A
H-D-DA-S-T-3 image