Pacific Hospital Double Action Door Set Installation
This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.
Installation wall framing requirements
Pacific Hospital Double Action Door Set
Frame materials available:
- EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
- Stainless Steel - 1.5mm
Recommended Fasteners:
- Frame screwed to stud through packing.
- Frame to be screw fixed (10g x 100mm self tapping) at 600mm nominal centres. Two fasteners per location
Head Fixing:
Single door: None required
Pair door: Double central fasteners
Wedging gap:
- 5-10 mm

Frame materials available:
EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
- Stainless Steel - 1.5mm
Recommended Fasteners:
Frame screwed to stud through packing.
Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location
Head Fixing:
Single door: None required
Pair door: Double central fasteners
Wedging gap:
- N/A

Frame materials available:
- EGZ - 1.6mm
- Cold rolled galvanized - 1.6mm
- Stainless Steel - 1.5mm
Recommended Fasteners:
Frame screwed to stud through packing.
Frame to be screw fixed (10g x 50mm self tapping) at 600mm nominal centres. Two fasteners per location
Head Fixing:
Single door: None required
Pair door: Double central fasteners
Wedging gap:
- N/A