Pacific PFL60 Fuego-Light Steel Glazed Fire Door Set -/60/30sm
The Pacific Forster FuegoLight -/60/30 is a high visibility fire door set. It comprises a side hung, fully glazed single or pair leaf. The leaf is hung on seam welded steel hinges in a steel frame.
The thickness of the door leaf is 65 mm. Approximate doorset weight (leaf plus frame) is 76 kg/m2
Wall Type | Fire Resistance Rating Stability/Integrity/Insulation |
Door Application | Max Leaf Height (mm) |
Max Leaf Width (mm) |
Steel Stud Wall Timber Stud Wall Masonry Wall |
-/60/30sm | Single | 2526 | 1161 |
Pair | 2526 | 1161 |
Notes:
- Please note that the maximum leaf width shown above is measured per door leaf.
- The ‘sm’ above denotes that the door is available as a smoke control door set.
Product Options
Leaf Facings
This steel fire doorset is fully glazed and not available with any other facings.
Finish
Standard preparation for interior use is powder coating.
Standard preparation for exterior use is sandblasting followed by zinc arc spray (15 year weatherability grade) to leaf and frame.
Unit can be delivered with a powder coat finish or primed ready to paint.
Exterior Situations
The door set is tested to AS/NZS 4284:2008 – “Testing of building facades” and complies with requirements of NZS 4211:2008 – “Specification for performance of windows” up to and including the High Wind Zone.
Hardware
Locks & Handles
This door set uses standard Forster lock and handles only.
The Forster lock fits any standard europrofile lock cylinder and comes in two versions; regular and panic exit.
Panic exit / free egress only available on push side of door.
No other latching hardware is approved on this door set.
Closer
Dorma TS93B SG5-7 closer mounted on either face.
For pair door sets closers have to be mounted on the pull side of the leaves.
Hinges
The leaf is hung on two seam welded steel hinges.
Access control
The Effeff 143 (fail secure) electric strike is approved for use on single doors only, not pairs.
Frame Types & Profiles
Steel Frame
The leaf is hung in a frame of 1.5 mm cold formed steel box sections.
Standard frames are three-sided only with no sill. Four-sided frames are available on request. Custom sills are not available for this door type. For more in depth information on frame profiles and sizes, please see our Installation Instructions.
Meeting Stiles
This door set is available with rebated meeting stiles only. This is only applicable to pair door sets.
Wall Types
The Pacific steel fire door set -/60/30 is suitable for installation in timber or steel stud plasterboard walls and masonry fire rated walls. Walls to be fire rated to minimum -/60/30 by others.
The standard installation method for steel or timber stud walls is by 12g screws at max. 450 mm centres.
The standard for Masonry installation is M8 Excalibur screwbolts (or similar) at max. 450 mm centres. No fasteners are exposed to weather or attack face.
Product Optional Extras
Vision Panels
Glazing Type | Maximum Glazed Area | Max Height (mm) | Max Width (mm) | Glazing Bead | FRR | |
Steel | Aluminum | |||||
Pyrobel 17N | 2.416 m2 | 2366 | 1021 | √ | -/60/30 |
Notes:
- Sizes noted above are the clear view.
- Glazing is Grade A safety glass
Single Leaf Door Sets
Sidelights and Overlights
Sidelights with a clear view width of up to 1376 mm can be added to either side of the leaf. Multiple sidelights can be stacked horizontally with no limit to overall width.
One overlight can be added above the leaf. The overall height of the unit is limited to 4259 mm for interior doorsets and 3993 mm for exterior doorsets.
SIDELIGHTS AND OVERLIGHTS
Additional Door Options
Push or Kickplates
Push or Kickplates are not available on this door set.
Ventilation Grilles
Ventilation grilles are not available on this door set.
Thermal Insulation
The glazing used in this window has a thermal insulation rating (R-value) of 0.185 Km2/W
Changes to the NZBC H1 “Energy efficiency” will come into effect gradually starting from November 2022, featuring more stringent requirements for the thermal insulation values of all exterior glazed windows and doors. As a result, some of our products may not be suitable for all climate zones or building types. Customers should take care to specify a suitable product for each specific project and Pacific Doors take no responsibility for incorrect products being selected. Thermal insulation R-values for all our exterior glazing products are listed on the Pacific Doors website.