Pacific Single Glazed Acoustic Windows SPA39-AW Installation
This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.
Installation wall framing requirements
Pacific Single Glazed Acoustic Windows SPA39-AW
Frame materials available:
- Timber (any species), Pine clear standard
Recommended Fasteners:
- Timber & steel studs - Screwed (10g x 50mm self tapping) at 600mm centres nominal. Minimum of one screw per location.
- Steel stud only - Frames may also be installed by screw fixing the steel studs to the back of the timber frame during wall construction.
Stud Size:
- Stud to suit acoustic wall system of equal or greater rating required.
Wedging gap:
- 0-10mm
Frame materials available:
- Timber (any species), Pine clear standard
Recommended Fasteners:
- Jamb fixing at 600mm centres nominal
- Expansion anchors eg. M10 countersunk 'Ramset' Dynabolts
- M12 countersunk masonry screwbolts
- Architrave -nailed (50 x 3.2mm) at 400mm centres.
Wedging gap:
- 0-10mm