Pacific SPW-1 Security Window Installation

 

This tool is designed to filter the available results as you search. Once you have applied a filter, you may need to reset the filter to be able to see all other available options.

To see our installation videos please click here.

Installation wall framing requirements

Pacific SPW-1 Security Window

WALL TYPE: Timber stud
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 2.0mm
  • Cold rolled galvanized - 2.0mm

Fasteners:

  • M12 Screwbolt anchors through adjustable spacer fixing bracket. Fixings at 600mm centres nominal. The length of bolts MUST be confirmed on site to suit the frame openings formed.
  • Bead - Tamper-resistant fixing screws or rivets at 400mm centres.

Stud size:

  • Ex 100 x 50 minimum

Wedging gap:

  • 0-10mm
S-W-SPW1-S-T image
WALL TYPE: Masonry
FRAME TYPE: Steel, 1-part

Frame materials available:

  • EGZ - 2.0mm
  • Cold rolled galvanized - 2.0mm

Fasteners:

  • M12 Screwbolt anchors through adjustable spacer fixing bracket. Fixings at 600mm centres nominal. The length of bolts MUST be confirmed on site to suit the frame openings formed.
  • Bead - Tamper-resistant fixing screws or rivets at 400mm centres nominal.

Wedging gap:

  • 0-10mm
S-W-SPW1-S-M image